Grand SPI gas meter with a telemetry system
Our dealersPurpose:
Grand SPI gas meters with telemetry systems are used for:
- measuring the volume of natural gas or liquefied gas vapours;
- electronic correction of consumed gas volume;
- remote data exchange with dispatching station.
Field of application:
Commercial metering of consumed gas:
- at utility and household facilities;
- at industrial facilities?
where the ambient temperature value can reach minus 30.
Can be installed:
-
in unheated premises;
-
outdoors in areas without direct entry of sunlight.
Data recording and reports printing allow using the meters for metering gas consumption by legal entities.
Features:
-
Data transfer to a dispatcher station via a GPRS channel;
-
The meter can be incorporated into the automated gas metering system;
-
Full-range electronic temperature, pressure and gas composition correction;
-
Archiving and printout of archives of consumption, contingencies, events, gas composition; Ergonomics (substitutes 3 articles: meter, corrector, modem);
-
Can be installed outdoors;
-
Moderate price.
Configuration:
By the colour of protective cover:
-
White;
-
Gray;
-
Orange.
Based on overpressure limit:
- Maximum overpressure up to 5 kPa;
- Maximum overpressure up to 300 kPa.
Based on ambient temperature:
-
From minus 20°C to plus 60°C;
-
From minus 40°C to plus 60°C.
Based on reduction to standard conditions:
-
T-gas volume correction by the method T-conversion;
-
TP-gas volume correction by the method TP-recalculation;
-
TPz-gas volume correction by the method TPz-recalculation.
Characteristic | Grand SPI-4 | Grand SPI-6 | Grand SPI-10 | Grand SPI-16 | Grand SPI-25 | Grand SPI-40 | Grand SPI-65 |
Maximum flowrate, Qmax, m3/h | 4 | 6 | 10 | 16 | 25 | 40 | 65 |
Measurement range | 1:100 | 1:140 | 1:160 | 1:250 | |||
Limits of permissible relative error during gas volume measurement, % in the flow rate range: | |||||||
Qmin < Q < 0.2 Qmax: 0.2 Qmax < Q < Qmax |
± 2.5 |
||||||
Range of measurements of volumetric flow rate reduced to the standard conditions, m3/h | оfrom 0.029 to 18.79 | from 0.032 to 28.19 | from 0.046 to 46.98 | from 0.074 to 75.17 | from 0.074 to 117.5 | from 0.118 to 188.0 | from 0.191 to 305.5 |
Sensitivity threshold | 0.5 Qmin | ||||||
Limits of permissible relative error during calculation of gas volumetric flow rate and volume, reduced to the standard conditions, % | ± 0.02 | ||||||
Limits of permissible absolute error during temperature measurement, °C | ±(05+0.002*|t|), where t-measured temperature,С | ||||||
Limits of permissible relative error during pressure measurement, % | ± 0.25 | ||||||
Range of working medium temperatures, °C | from minus 20 to plus 60 | ||||||
Range of ambient temperatures, °C |
from minus 40 to plus 60 from minus 20 to plus 60 |
||||||
Time between failures, hours, at least | 80,000 | ||||||
Average service life, years, at least | 10 | ||||||
Joining thread of coupling nut, G |
3/4; 1 | 1; 1 1/4 | 1 1/4; 2 | ||||
Overall dimensions (length, width, height), mm, not more than |
193*110*112 | 220*135*116 | |||||
Weight, kg | 3.0 | 3.5 | 4.0 |