Gas flowmeters Turbo Flow UFG-F compact version (up to 1.6MPa)
Our dealersUltrasonic gas flowmeters are intended for high-accuracy measurement (1%) volumetric gas flow rate, mass gas flow rate, in operating and standard conditions in pipelines DN 50...100 mm PN16. Field of application ultrasonic gas flowmeters Turbo Flow UFG-F compact version unit of gas metering stations in gas distribution networks with pressure up to 1.6 MPa, modernization and re-equipment of metering units with measurement systems based on the turbine and rotary meters with electronic correctors and gas metering device nodes in the absence of power.
Purpose: |
|
Ultrasonic gas flowmeters are intended for high-accuracy measurement (1%):
in operating and standard conditions in pipelines DN 50...100 mm PN16. The electronic computing unit:
|
![]() |
Field of application : |
|
|
|
Specific features of flowmeter: |
|
|
|
Our engineers together with the researchers from the South Federal University carried out a series of studies in the ultrasonic flow measurement field. The twoyear effort has resulted in a unique measuring system based on the special-purpose piezoelectric transducers that are not sensitive to contaminating deposits up to 1 mm thick. This offers the possibility to successfully use our flowmeters for metering so-called "dirty gas". | ![]() |
![]() |
|
Gas flowmeters Turbo Flow UFG-F compact version (up to 1.6MPa) |
Configuration options: |
Based on temperature range of ambient environment and medium measured:
|
Based on components and performed functions:
|
Based on explosion protection:
|
![]() |
A special-purpose removable attachment allows performing the on-site "hot" swapping of ultrasonic sensors without pressurizing the main pipeline and without dismantling the flowmeter. |
Additional equipment: | |||
![]() |
![]() |
![]() |
|
Flow-measurement cabinet |
Device to replace |
Straight sections |
Metrological performance:
Characteristic | Value |
Range of gas flow rate measurement, m3/hour | from 1.5 to 1,100 |
Dynamic range Qmin/Qmax | 1:200 |
Limits of permissible relative error when measuring volumetric flow rate and volume of gas in operating conditions, for combination of pairs of transmitter/receiver units within range of flow rates Qmin<Q< 0.01 Qmax |
2.0 |
0.01 Qmax<Q< Qmax | 1.0 |
Gas overpressure range, MPa | 1.6 |
Performance specification:
Characteristic | Value |
Digital wired interfaces |
protocol MODBUS RTU |
Digital wireless interfaces |
GSM, GPRS |
Operating conditions: -ambient air temperature, °С for Configuration М for Configuration Х |
from - 30 to + 70 from - 50 to + 70 |
- relative air humidity, %, |
up to 95 from 84.0 to 106.7 |
Average mean time between failures, hours, at least |
70,000 |
Download software
Name | Instruments | Files name | Size,byte |
---|---|---|---|
DOTNET 4.0.3 | Driver |
DotNetPack_403ru | 124 147 694 |
XGViewer_1.2.45 | UFG-BP20 UFG-RL-EK |
XGViewer_1.2.45 | 15 287 360 |
The report on the implementation of the scientific research and experimental design work jointly with OOO "Gazprom Transgaz Moscow" on the topic: "Gas flow measurement system at the entrance of Automotive gas-filling compressor stations (AGFCS)" RUS.
Protocol test gas meter ultrasonic flow meter Turbo Flow UFG on the basis of LLC "Gazprom Transgaz Stavropol"